home *** CD-ROM | disk | FTP | other *** search
/ Software Vault: The Gold Collection / Software Vault - The Gold Collection (American Databankers) (1993).ISO / cdr11 / intmemry.zip / MEMO1128.TXT < prev    next >
Text File  |  1992-12-02  |  11KB  |  241 lines

  1.   ╔═════════════════════════════════════════════════════════════════════════╗
  2.   ║                                                                         ║
  3.   ║           ISA Bus: Computer Compatibility: 80286-Based: N-S             ║
  4.   ║                                                                         ║
  5.   ╚═════════════════════════════════════════════════════════════════════════╝
  6.  
  7. NCR PC8, PC8-10
  8.  
  9.   *CUSTOMER REPORTS* of compatibility between this 80286-based system and
  10.   current Above Boards and Matched Memory Classic boards. There are also
  11.   reports of comptibility with the discontinued Above Board 286, PS/286, AT,
  12.   and PS/AT. The NCR system board has jumpers which must be set for only the
  13.   actual memory on the system board.  Do not include any Intel memory board
  14.   amounts when determining jumper setting.  Make sure bus is set at 1 wait
  15.   state.
  16.  
  17. NEC POWERMATE I
  18.  
  19.   *CUSTOMER REPORTS* of compatibility between this small-footprint 80286-
  20.   based computer and current Above Boards and Matched Memory Classic boards.
  21.   There are a couple versions of this system.
  22.  
  23.   8 Mhz Version: 8mhz, 1 wait state bus.  Customer reports intermittent
  24.   parity errors when SETBOARD is set for 8mhz.  Set the AB for 10mhz, 150ns
  25.   chips.
  26.  
  27.   8/10 Mhz Version: Bus speed follows processor speed.  Set the Intel Memory
  28.   card for 10mhz, 150ns chips (in SETBOARD).
  29.  
  30.   When this NEC system is set for 8mhz, the bus is operating at 8mhz with 1
  31.   wait state. When the system is set for 10mhz, the bus is operating at
  32.   10mhz with 2 wait states.
  33.  
  34. NEC POWERMATE I PLUS
  35.  
  36.   *CUSTOMER REPORTS* of limited compatibility with current Above Boards and
  37.   Matched Memory Classic boards in these small-footprint 80286-based
  38.   computers. These computers operate an 8 MHz data bus running at the IBM
  39.   Standard 1 wait state, switchable to 12 MHz and a non-standard 0 wait
  40.   states.
  41.  
  42.   Customers report Intel memory cards work at 8 MHZ but give intermittent
  43.   parity errors when set at 12 MHZ, probably due to the non-IBM AT Standard
  44.   0 wait state bus.
  45.  
  46. NEC POWERMATE 286 PLUS
  47.  
  48.   *CUSTOMER REPORTS* of INCOMPATIBILITY with current Above Boards and
  49.   Matched Memory Classic boards in these 80286-based computers.
  50.  
  51.   Tech Notes: System apparently runs at 8 or 12MHz. It has 1meg of memory on
  52.   the system board. The system board memory is divided into 640K of
  53.   conventional memory and 384 reserved for system use, (might be
  54.   configurable for onboard EMS memory). This system runs it's data bus at 0
  55.   wait states instead of the IBM Standard of 1 wait state. It is over the
  56.   lack of IBM Standard wait states that Intel memory boards are
  57.   incompatible.
  58.  
  59. NEC APC IV POWERMATE (8MHZ)
  60.  
  61.   Compatible with current Above Boards, Matched Memory Classic boards, and
  62.   the discontinued Above Board 286 and PS/286.
  63.  
  64.   Specify that the system is 10MHz in Setboard (even though it runs at
  65.   8MHz).  If Automatic setboard is used, or if 8MHz is specified, the AB
  66.   will not install properly.
  67.  
  68.   NEC reports full compatibility with the discontinued Above Board AT & AB
  69.   PS/AT.
  70.  
  71. NEC APC IV POWERMATE II (10MHZ)
  72.  
  73.   Compatible with current Above Boards, Matched Memory Classic boards, and
  74.   the discontinued Above Board 286 & PS/286.
  75.  
  76.   In Setboard and specify 10mhz bus speed.  If Automatic setboard is used,
  77.   or if 8MHz is specified, the Intel memory card will not install properly.
  78.  
  79. NORTHERN TELECOM M6000
  80.  
  81.   *CUSTOMER REPORTS* of compatibility between current Above Boards and
  82.   Matched Memory Classic boards in these 8MHZ 80286-based computers.  These
  83.   systems are switchable between a non-IBM AT Standard 0 wait state bus or 1
  84.   wait state.  Set computer for 1 wait state when installing Intel memory
  85.   boards.
  86.  
  87.   Customers also report EMM 3.5 with an Above Board 286 causes lock ups in
  88.   these computers, newer versions of our software seem to work fine.
  89.  
  90. NORTHGATE 286
  91.  
  92.   Compatible with current Above Boards and Matched Memory Classic boards.
  93.  
  94.   Tech Note: If system freezes after installing expanded memory, check for
  95.   Northgate 16-bit VGA board and switch it to 8-bit ROM by turning SW6 to
  96.   OFF.
  97.  
  98. NOVELL 286B FILE SERVER
  99.  
  100.   INCOMPATIBLE with Above Boards and Matched Memory Classic boards.
  101.   Dealer reports:  This system has 16-bit slots, but will not support AT-
  102.   compatible add-in extended memory boards such as the Above Boards or
  103.   Matched Memory Classic boards. Must use Novell's proprietary extended
  104.   memory boards.
  105.  
  106. PACKARD BELL PBVT286B
  107.  
  108.   Compatible with Current Above Boards and Matched Memory Classic boards.
  109.   This is an 80286-based 6-10Mhz computer.  Customer must run SETBOARD and
  110.   choose the 10Mhz option.  This system is NOT compatible with the
  111.   discontinued Above Board AT or  PS/AT.
  112.  
  113. PANASONIC FX-800
  114.  
  115.   *CUSTOMER REPORTS* of compatibility with current Above Boards and Matched
  116.   Memory Classic boards in these 80286-based computers. These desktop
  117.   computers can operate at  6 or 8MHz.
  118.  
  119.   Customers also report of compatibility with the discontinued Above Board
  120.   286, PS/286,  AT, and PS/AT.
  121.  
  122. PC'S LIMITED AT
  123.  
  124.   This 6 or 12MHz 80286-based computer is compatible with current Above
  125.   Boards and Matched Memory Classic boards. Also compatible with the Above
  126.   Board 286 and PS/286.  Only compatible with the Above Board AT and PS/AT
  127.   at the 6MHz speed.
  128.  
  129.   Tech notes: One customer reported when using an Above Board 286 in a
  130.        12mhz system they would get lockups when the hard disk was
  131.        accessed or after EMM has just finished installing.
  132.   The SOLUTIONS:
  133.   ■    Booting the system at the lower speed (6mhz) then switching the
  134.        system to the higher speed.
  135.   ■    Additionally,  if the Above Board providing expanded memory is NOT
  136.        providing any extended memory then the "NE" parameter may be added
  137.        to the EMM command line.
  138.  
  139. PC'S LIMITED 286/12MHZ
  140.  
  141.   *CUSTOMER REPORTS* of compatibility with the Above Board ISA, Plus, PLus
  142.   8, and the Matched Memory Classic in these 80286-based computers. Make
  143.   sure the Intel memory board is set for the 12mhz data bus speed (with
  144.   HWSETUP for the Above Board ISA, or SETBOARD with the Above Board Plus,
  145.   Plus 8, and the Matched Memory Classic).
  146.  
  147.   Common Symptom in this computer:  Testab reports 2 banks bad, probably has
  148.   specified a bus speed of 6/8mhz in Setboard; setting to 12MHz should work
  149.   fine.
  150.  
  151.   Tech Notes:
  152.   The Above Board ISA cannot map any memory into the address range E000-EFFF
  153.   on the PC's Limited 286/12 because there is BIOS ROM from E800-FFFF that
  154.   sets the entire E000- range for 16-bit system board accesses.
  155.  
  156. PC-DESIGNS TURBO AT
  157.  
  158.   *CUSTOMER REPORTS* of LIMITED compatibility with current Above Boards and
  159.   Matched Memory Classic boards in this 80286-based computer. The system
  160.   will not do warm boots with EMM installed.  All other functions operate
  161.   correctly.
  162.  
  163. PC DESIGNS MODEL 120
  164.  
  165.   One customer reports that an Above Board 286 worked fine with manual
  166.   installation of software in this 80286-based computer. We have no
  167.   information at all about compatibility with these computers and current
  168.   Above Boards and the Matched Memory Classic boards, although we can't
  169.   foresee any problems.
  170.  
  171. PHILLIPS P3202
  172.  
  173.   *CUSTOMER REPORTS* of compatibility between these 80286-based computers
  174.   and current Above Boards and Matched Memory Classic boards. Also have
  175.   reports of compatibility with the Above Board 286 and PS/286.
  176.  
  177.   This computer is sent from the factory with the Non-IBM AT standard of 0
  178.   wait states.  Must insert a wait state by removing jumper W12 on the
  179.   mother board.  (The power supply has to be removed to get to this jumper).
  180.  
  181. SAMSUNG 10MHZ
  182.  
  183.   *CUSTOMER REPORTS* of compatibility between current Above Boards and
  184.   Matched Memory Classic boards in these 80286-based computers. Probably not
  185.   compatible with the discontinued Above Board AT and PS/AT due to the fast
  186.   bus speed.
  187.  
  188.   One customer mentioned that there is no way to provide extended memory
  189.   with ANY add-in board if there are empty memory sockets on this
  190.   motherboard.  This system has sockets for 1Meg on the motherboard.
  191.  
  192. SAMSUNG S550 12MHZ
  193.  
  194.   *CUSTOMER REPORT* of compatibility with current Above Boards and Matched
  195.   Memory Classic boards. Probably not compatible with the discontinued Above
  196.   Board AT and PS/AT due to the fast bus speed.
  197.  
  198.   Tech Notes: Customer reports that the Samsung S550 12MHz AT is shipped
  199.   with a jumper marked J16 not set to the manufacturers default.  The
  200.   default is supposed to be J16 installed. This jumper controls the memory
  201.   size of the motherboard (J16 off = 1MB  J16 on = 640K).  There must be a
  202.   jumper on J16 AND 640K on the mother board in order for the AB to supply
  203.   EXTended memory starting at 1.0M!
  204.  
  205. SPERRY IT
  206.  
  207.   These 80286-based computers are compatible with current Above Boards and
  208.   Matched Memory Classic boards.  We also have reports of compatibility with
  209.   the discontinued Above Board AT, PS/AT, 286, and PS/286.
  210.  
  211.   With the INSTALL program (shipped prior to our LIM 4.0 software was
  212.   shipped), the EMM software had to be installed manually. The current
  213.   SOFTSET program should work fine.
  214.  
  215.   One customer reported his Above Board worked in 7.16MHz, 0 wait state
  216.   mode.
  217.  
  218.   Motherboard has sockets for 640Kb conventional memory which should be
  219.   filled if the customer wants 640Kb conventional memory.  Do not use any
  220.   add-in memory board to backfill conventional memory on this system, it was
  221.   designed to be filled by the motherboard only.
  222.  
  223.   This system does not display a BIOS memory test at boot so you will not
  224.   see extended memory count up on POST.
  225.  
  226.   If system locks up when EMM is loaded, try setting the board for 10MHz,
  227.   (Above Board 286, Plus, Plus 8 only and Matched Memory Classic only).
  228.  
  229. SPERRY MICRO IT
  230.  
  231.   This 80286-based computer is compatible with Current Above Boards, Matched
  232.   Memory Classic boards and the discontinued Above Board 286 and PS/286.
  233.   This computer has a 10MHz bus speed, make sure Setboard is told it will be
  234.   talking to a 10MHz bus. This system has been known to lock up when trying
  235.   to run SOFTSET, TESTAB, or when EMM is trying to load if the Above Board
  236.   is set to operate at a speed other than 10MHz.
  237.  
  238.  
  239. ══════════════════════════════════════════════════════════════════════════════
  240. End of file                 Intel FaxBack # 1128          December 2,1992